RE66176/2023-05-22,BoschRexrothAG
Contents
Features
Load-sensingsystem
Loadpressureindependentowcontrol
Compactdesign
Typeofactuation
Electro-hydraulicwithon-boardelectronics
Flow
Loadpressure-compensated
Highrepetitionaccuracy
Lowhysteresis
Fields of application
Tractors
Agriculturalmachinery
Attachments
Series2X
Maximumworkingpressure250bar
Maximumow80l/min
Load-sensing directional valves
in sandwich plate design
SB11-EHS4
RE66176/2023-05-22
Replaces:2022-04-05
CANbusinthetractor 2
Functionaldescription 3
Modularsystem 4
Technicaldata 5
Qualicationtesting(electric,EMC) 7
Hydraulicfunctions 9
Electronicfunctions 14
Dimensions 16
Installationposition 18
Relateddocumentation 19
Abbreviations 19
Spareparts 19
BoschRexrothAG,RE66176/2023-05-22
2
SB11-EHS4 |Directionalvalves
CANbusinthetractor
CAN bus in the tractor
Withtheincreaseinelectronicsintheeldofagricultural
tractors,theControllerAreaNetwork(CAN)developedby
Boschhasbecomeanestablishedmeansofdataexchange
amongtheindividualdevices.
Thisserialdatabusconnectsdeviceswithequalrightsand
coordinatesthedataexchangeintheformofdigitalCAN
messages.
CAN features of the EHS actuating unit
Self-diagnosticsandautomaticrepeattransmissionin
theeventofdamagedorincompletemessages
Linkingandthussimultaneouscommunicationpossible
amongseveralsensors,controlunitsanddisplayunits
Worldwiderecognizedstandard,ISO11898and
11519-2aswellasSAEJ1939
Lesscablingmakesforreducedinstallationspaceand
lowercosts,andreducesriskfordamages
Highfaulttoleranceandhighsecurityoftheinterface
Diagnosticsthroughoutputoferrorcodes
Barrier-freediagnosticaccessviaUDS
(UniedDiagnosticServices)accordingtoISO14229
CANFDtolerant
!
SRC
P
R
LS
CAN
CAN
1
2
6
7
8
9
10 11
t [ms]
I
Sig
[V]
3 4
5
1 Controlpanel
2 Operatingkeys
3 FrontEHR
4 RearEHR
5 Electroniccontrolunits
6 Instrumentcluster
7 Controlblock
8 CANsignal
9 CANmessage
10 ID
11 Signal
RE66176/2023-05-22,BoschRexrothAG
3 Directionalvalves | SB11-EHS4
Functionaldescription
Functional description
SB11-EHS4arepilot-operated,electro-hydraulically
actuateddirectionalvalveswithfourspoolpositions
andon-boardelectronics.
Thecontrolspooliscontrolledviaa4/3directional
pilotcontrolvalvewhichpressurizesthechambersfor
deectionofthecontrolspool.Thecontrolspoolposition
isguidedbackbymeansofapositiontransduceronthe
controlelectronics.Usingthecurrentofthepilotcontrol
valve,theelectronicsthenregulatethepositionofthe
controlspoolasafunctionofthesetpointvalueofthe
spooldeection.Inthisway,theowrequiredtooperate
theconnectedequipmentissetattheconsumerports.
Theindividualpressurecompensator(IPC)controls
aconstantpressuredifferenceviatheintakecontroledge
ofthecontrolspool,suchthatowcontrolindependentof
loadpressureisachievedovertheentireadjustingrange
(loadcompensation),eveninparalleloperation.
ThedirectionalvalveSB11-EHS4isequippedwith
acheckvalveinconsumerportB.
Themechanicallyactuatedisolatorvalveactsasacheck
valveintheinlet.IntheSB11-EHS4,thecheckvalve
functionfromtheconsumerportAisimplemented
viathethirdswitchingpositionofthe2/3-wayIPC.
ThispreventsreturnowinPintheeventofundersupply
inparalleloperation.
Features
Double-actingwithfourswitchingpositions(Neutral,
Lifting,Lowering,Float)
MechanicallyactuatedcheckvalveinconsumerportB
CheckvalveopenedinFloatwithoutloadpressure
2/3-wayindividualpressurecompensatorininlet
Optionalangesurfaceforcustomer-specic
couplinghousing
Optionalthermalpressurereliefvalveintegrated
inthecheckvalve
SB11-EHS4 with one check valve in portB
1237810 2 44
569
P
A
R
B
1 Checkvalve
2 Consumerports
3 Returnspring
4 Chamber
5 Individualpressurecompensator(IPC)
6 Controlspool
7 Circuitboard
8 Positiontransducer
9 Pilotcontrolvalve
10 Electricalconnectionofthepilotvalve(CANcontrol)
BoschRexrothAG,RE66176/2023-05-22
4
SB11-EHS4 |Directionalvalves
Modularsystem
Modular system
Theelectro-hydraulicdirectionalvalvesSB11-EHS4
arepartoftheSB11moduleandcanbecombined
optimallywithhitchcontrolvalvesEHR11-EHS4for
therelevantapplicationtoformcontrolblocks.
Forfurtherinformation,seedatasheet66177:
ControlblockSB11-EHS.
Thevalvesectionsareavailableintheversionsstandard
valve(SVR)withangesurfacesonbothsidesaswellas
endvalve(EVR)withoneangesurface.
End valve (EVR) and standard valve (SVR)
P
Y
R
SVREVR
P
R
A
B
A
B
Anendvalve(EVR)canbeusedinsteadofaseparate
endplate(withouthydraulicfunction).
Eachvalvesectionnotiesitsloadpressuretothevalve
thatfollowsviatheLSchannel.Itsshuttlevalvecompares
thetwoloadpressuresandsignalsthehigheroneinthe
directionoftheconnectingplate.Inthisway,thehighest
loadpressureofallvalvesectionsissignaledtothe
variabledisplacementpumpviatheLSoutputofthe
controlblock.ThedefaultsignalingdirectionoftheLS
signalis"right".
Block conguration SB11-EHS4 with connecting plate (AP),
standard valves (SVR) and end valve (EVR)
P
R
APSVREVR
A
B
A
B
SVR
A
B
SVR
A
B
LSsignal
tothepump
LS signaling direction "right"
Y
2
Y
1
Y
Y
2
Y
1
WV
1
WV
2
Y
Ports
P Pumpport
A, B Consumerport
X Pilotoilsupply
Rx Pilotoilreturn
Y LSsignal
R Returnowreservoir
Notice
ThePandRchannelsofEVRarepluggedwith
threadedplugsontheunmachinedvalveside.
Theseportsmustnotbeopenedand/orusedforthe
connectionofadditionalfunctions!
RE66176/2023-05-22,BoschRexrothAG
5 Directionalvalves | SB11-EHS4
Technicaldata
Technical data
General
Weight kg 4.5
Installationposition Seepage18
Lineconnections Seepage18
Ambienttemperaturerange
ϑ
°C –35…+80
Hydraulic
Nominalpressureatport P p
nom
bar 210
Max.workingpressureatport P p
max
bar 250
A, B p
max
bar 250
R, Rx p
max
bar 20
X p
max
bar 50
Neutralcirculationpressurefor
openingtheIPCfromthe
checkfunction
P→R
p
bar 2.8atq
Vnom
=60l/min
6.2atq
Vnom
=80l/min
Flow
at
port
P→A,B q
vnom
l/min 60,80
A, B→R q
vmax
l/min 142
Leakage A→R q
L
ml/min ≤60
without
checkvalveinA
B→R q
L
ml/min ≤2withcheckvalveinB
Crackingpressureofthermalpressurereliefvalve(optional)
p
bar 311±69
Pilotoilpressure Referencedtoreturn
owpressure
bar 17…22
Pilotoilowperdirectional
valve(typical)
Neutral l/min 0.25
Controlposition
Lifting/Lowering
l/min 0.6
Momentaryatmax.
actuatingspeed
l/min 3.5
Hydraulicuid
Mineraloil(HL,HLP)accordingtoDIN51524,
seedatasheet90220.Otherhydraulicuidsonrequest,
e.g.environmentallyacceptableuidsperISO15380
asspeciedindatasheet90221.
Hydraulicuid
temperaturerange
Maximum
ϑ
°C −35…+110
Recommended
1)
ϑ
°C +35…+80
Viscosityrange Maximum
ν
mm²/s 7…8000
Recommended
1)
ν
mm²/s 20…100
Maximumadmissibledegreeofcontaminationofthehydraulicuid
CleanlinesslevelperISO4406(c)
Level20/18/15,werecommendalterwithaminimum
retentionrateofβ
10
≥75
Notice
Forapplicationsoutsidethesevalues,
pleaseconsultus!
Thetechnicaldataweredeterminedwith
aviscosityrangeofν=30mm
2
/sand
atemperatureofϑ=50°C.
Notice
Thestatedcheckvalveleakagevaluesreferto
apressureofp=125bar.
Inthecaseofexternalpilotoilsupply,mixingofthe
pilotoilcircuitwiththeoperatingoilcircuitcannotbe
avoidedfordesignreasons.
1) Anyoperationoutsidetherecommendedrangesmayaffect
servicelifeandfunction.
BoschRexrothAG,RE66176/2023-05-22
6
SB11-EHS4 |Directionalvalves
Technicaldata
Electro-hydraulic
Standard CANcontrol
Relativedutycycle(ED) 100%EDto+110°C
1)
Inputsignal CAN,physicallayeraccordingtoISO11898"HighSpeed"
125
kBd,250kBd(default),500kBd,1000kBd
Supplyvoltage
Vehicleelectricalsystem
accordingtoISO16750-2:CodeD
V 12
Electricalpowerconsumption IfU
Bat
=14V
Typical max.
InNeutralposition W 1.2 1.5
Duringmax.actuatingspeed W 20
Inposition1or2 W 4.0 5.0
InFloatmode W 14 20
Voltagerange
Normalvoltagesupplyrange V 10.5…16
Undervoltagemode:
Restrictions
infunctionanddynamics
V 9.5…10.5
Verylowvoltagemode:
Only
CANcommunicationisguaranteed
V 6…9.5
Nofunction,µCisreset,outputsareoff V <6
Overvoltageresistance(supplyvoltage) V 26(duration5min)
Reversepolarityprotection(testvoltage) V 18(duration1min)
Shortcircuitresistance Against16V,againstground,andbetweentheindividual
inputsandoutputs,duration5min
Systemstart-uptime Firstloginmessage→
ready
forcommunication:
ms 500
Actuatingtimefor100%
deection
Seecharacteristiccurveonpage12
Actuatingtime/dynamics(measuredat50°C,30mm
2
/s,VG46)
Stepfunction
(incl.
deadtime)
2)
0→1/2 ms 70
0→F ms 100
Hysteresisrelativetoow Typicallyapprox.1%ofq
nom
(in
owrangeupto80%ofq
nom
)
Sinusvibrationtest DINEN60068-2-6(sinustesting)
Frequency Hz 10…2000,acceleration:10g
Duration/axis Hrs 8
Broadbandnoisetest DINEN60068-2-64,5...2000Hz,a
eff
86.9m/s
2
Shocktest DINEN60068-2-27,a=500m/s
2
,11ms,60cycles
DINEN
60068-2-29,a=400m/s
2
,6ms,300cycles
Conformitywith EMCdirective2014/30/EU
withCEmarking
Appliedstandards:
ENISO14982:2009
Connectorversion AMPSuperseal,4-pin
Pinassignment
Pin1=ground
Pin2=CANhigh
Pin3=CANlow
Pin4=U
Bat
Pin 2
Pin 1
Pin 3
Pin 4
1) Detailedinformationonrequest
2) Seecharacteristiccurveonpage12
RE66176/2023-05-22,BoschRexrothAG
7 Directionalvalves | SB11-EHS4
Qualicationtesting(electric,EMC)
Electro-hydraulic
Typeofprotection IP66,IP67,IP69K
(with
installedandlockedplug-inconnector)
Required components(notincludedinthescopeofdelivery) Material no. TYCO Quantity
AMPSupersealconnector 282088-1 1
ContactMINI-MICforconductorcrosssection0.75…1.5mm²
andinsulationdiameter1.7…2.4mm
282110-1 4
Insulationdiameteroftheindividualsealsfrom1.7...2.4mm 281934-2 4
Recommendedcableprotection 493581-1 1
Generaldata Tycoproductspecication108-20090
Prescribedlinetype FLR
Selectanappropriateconductorcrosssectionforcontact,individualsealandpowerconsumption.
Thewiringharnessmustbemechanicallysupportedintheinstallationarea(freelength<150mm)ofthevalve.
In-phase
energizationofthevalvetosupportthewiringharness.
Notice
TheOBEisdesignedforaservicelifeof10years
operatingtimeand5yearsstoragetime(withinthe
recommendedtemperaturerange).Afterthistime,
theprobabilityoferrormayincrease.
Theoperatingtimeisnotmonitoredbythe
on-boardelectronicsitself.Themachinemanufacturer
isresponsibleformonitoringanddeningsuitable
measures(e.g.testormaintenanceintervals).
Qualication testing (electric, EMC)
Susceptibility EMC tests
ISO11452-2:2019: Absorber-linedshieldedenclosuremethod
complieswithUNECE10Rev.6
Supplyvoltage: 13.5V
CW200MHz…3GHz,100V/m
AM200MHz…800MHz,150V/m
PM800MHz…3GHz,150V/m
ISO11452-4:2011: BCItestmethodcomplieswithUNECE10
Rev.6
Supplyvoltage: 13.5V
1…20MHz: 200mA
1)
20…400MHz: 200mA
Method: Openloop,commonmode
(complete
harnessincurrentprobe)
Emission EMC test
UNECE10Rev.5: Broadbandemittedinterference;
chapter
6.5,appendix6
Supplyvoltage: 13.5V
UNECE10Rev.5: Narrowbandemittedinterference
chapter6.5,appendix6
Supplyvoltage: 13.5V
CISPR25:2008: Radiatedemissionchapter6.4.4
Supplyvoltage: 13.5V
Class3: 80MHzand212MHz,
other
frequenciesclass4
CISPR25:2008: Conductedemissionchapter6.2.3,
table5
and6
Supplyvoltage: 13.5V
Class3: 1MHzand69…76MHz,
other
frequenciesclass4
UNECE10Rev.6,ISO7637-2:2011,ISO7637-2:2004:
Voltage
transientemissiontest
Supplyvoltage: 13.5V
LevelIII
BoschRexrothAG,RE66176/2023-05-22
8
SB11-EHS4 |Directionalvalves
Qualicationtesting(electric,EMC)
Electrostatic discharge (ESD) tests
ISO10605:2008
Supplyvoltage:
Testvoltage:
Operatingstate:
Directcontactdischarge
13.5V
TableC.1,category1,L1toL4
(max.
±8kV)
C(active)
ISO10605:2008:
Supplyvoltage:
Testvoltage:
Operatingstate:
Directairdischarge
13.5V
TableC.2,category1,L1toL4
(max.
±15kV)
C(active)
ISO10605:2008:
Testvoltage:
Operatingstate:
Contactdischarge,notpowered
TableC.1,category1,L1toL4
(max.
±8kV)
Aafterreset(passive)
ISO10605:2008:
Testvoltage:
Operatingstate:
Airdischarge,notpowered
TableC.2,category1,L1toL4
(max.
±15kV)
Aafterreset(passive)
Transient tests
ISO7637-2:2011:
Supplyvoltage:
U
S
:
Operatingstate:
Testpulse1
13.5V
+600V
C(active)
ISO7637-2:2011:
Supplyvoltage:
U
S
:
Operatingstate:
Testpulse2a
13.5V
+200V
A(active)
ISO7637-2:2011:
Supplyvoltage:
U
S
:
Operatingstate:
Testpulse2b
13.5V
−450V
A(active)
ISO7637-2:2011:
Supplyvoltage:
U
S
:
Operatingstate:
Testpulse3a
13.5V
−450V
A(active)
ISO7637-2:2011:
Supplyvoltage:
U
S
:
Operatingstate:
Testpulse3b
13.5V
+200V
A(active)
ISO7637-2:2011
(ISO16750-2:2012):
Supplyvoltage:
LevelIVU
s
:
Operatingstate:
Startingprole(pulse4)
12V
−7V
C(active)
ISO7637-2:2004:
Supplyvoltage:
LevelXU
s
:
Operatingstate:
Startingprole(pulse4)
12V
−7V
C(active)
Transient tests
ISO16750-2:2012:
Supplyvoltage:
U
S
:
R
i
:
t
d
:
Operatingstate:
Table5(pulse5a)
13.5V
+202V
8Ω
350ms
C(active)
ISO16750-2:2012:
Supplyvoltage:
U
S
:
R
i
:
t
d
:
Operatingstate:
Table6(pulse5b)
13.5V
+50V
1Ω
350ms
C(active)
ISO7637-2:2016:
Supplyvoltage:
MethodCCC,LevelIV:
U
S
:
Operatingstate:
Fastpulsesaandb
13.5V
−110V/+75V
A(active)
ISO7637-3:2016:
Supplyvoltage:
MethodICC,LevelIV:
U
S
:
Operatingstate:
Slowpulsespositiveandnegative
13.5V
−6V/+6V
A(active)
General electrical tests
ISO16750-2:2012:
U
Smax
:
Duration:
Operatingstate:
Shortcircuitofsignals,chapter4.10.2
18V
5min
D
ISO16750-2:2012:
U
sup
:
Operatingstate:
Overvoltage,chapter4.3.2
18.5V
C
ISO16750-2:2012:
Case2,U
A
:
Operatingstate:
Reversedpolarity,chapter4.7.2
−18V
Aafterreset
RE66176/2023-05-22,BoschRexrothAG
9 Directionalvalves | SB11-EHS4
Hydraulicfunctions
Hydraulic functions
Example congurations SB11-EHS4
Type Features
B
A
F 2
2.F
0 1
RxXPR Y
Standardvalve(SVR)
CheckvalveinB
Withoutthermalpressurereliefvalve
B
A
F 2
2.F
0 1
RxXPR Y
Endvalve(EVR)
CheckvalveinB
Withoutthermalpressurereliefvalve
0=Neutral
1=Lifting
2=Lowering
F =Float
BoschRexrothAG,RE66176/2023-05-22
10
SB11-EHS4 |Directionalvalves
Hydraulicfunctions
Switching capacity limits
Themaximumswitchablereturnowisdependent
ontheloadpressurelevel.Theowforcesatthe
spoolhavealimitingeffecthere.
Thevaluesrepresentedrefertothepilotpressure17bar.
Characteristic curve return ows, switching capacity limits
Flowq
V
[l/min]
Δp[bar]
96; 185
142; 50
142; 0
0
50
100
150
200
250
0 20 40 60 80 120 140100 160
0; 200
Flow resolution
Thecharacteristiccurvesapplyforstandardversions
(owedgecomparison).
Othertolerancescanoccurforspecialversionsor
specialspoolversions.
Characteristic curve for ow resolution
0
0.5
1.0
1.5
2.0
2.5
0 20 40 60 80 100
1
2
3
4
Flowq
V
[l/min]
Flowresolution[l/min]
1 q
nom
=60l/min(typical)
2 q
nom
=60l/min(maximum)
3 q
nom
=80l/min(typical)
4 q
nom
=80l/min(maximum)
Forreturnowedgecomparison,thetolerancesonlyapply
above10%ofthenominalow(greatertolerancesareto
beexpectedbelowthisvalue).
Hysteresis
Withrespecttotheow:
Typicallyapprox.1%ofq
nom
(inowrangeupto80%ofq
nom
)
Maximum2%ofq
nom
Temperature drift of ow
Thetemperaturedependenceoftheowiscompensated
electronicallyinthetemperaturerange30°Cto90°C.
Pressure drift of ow
Pressuredriftoftheow(pressureincreasedueto
paralleloperation)iscompensatedbytheindividual
pressurecompensator.
RE66176/2023-05-22,BoschRexrothAG
11 Directionalvalves | SB11-EHS4
Hydraulicfunctions
Flow resistances (typical values)
SB11-EHS4, 1 check valve
Position 1 (Lifting)
Flowq
V
[l/min]
PressuredropΔp[bar]
0
0
4.5
7.4
6.9
10.6
20.8
5
10
15
20
25
30
35
40
45
20 40 60 80 100 120 140 160
Y B
A R
Position 2 (Lowering)
Flowq
V
[l/min]
PressuredropΔp[bar]
0
0
5
10
15
20
25
30
35
40
45
20 40 60 80 100 120 140 160
3.4
6.1
14.0
21.5
42.5
Y A
B R
Position F (Float)
Flowq
V
[l/min]
PressuredropΔp[bar]
0
0
5
10
15
20
25
30
35
40
45
20 40 60 80 100 120 140 160
14.2
28.2
9.3
14.4
28.6
A R
B R
BoschRexrothAG,RE66176/2023-05-22
12
SB11-EHS4 |Directionalvalves
Hydraulicfunctions
Pilot pressure
p
X
=17to22bar
(settingpointforcontrolow0.8to1.2l/min)
Thepilotpressureinaccordancewiththediagrammustbe
availablealonetotheEHSvalves,sincethefullvalve
performanceisotherwisenotguaranteed.
Characteristic curve for pilot pressure
0
2
4
6
8
10
12
14
16
18
20
22
24
0 2 4 6 1081 3 5 7 9
maximum
minimum
Setting
Controlow[l/min]
Pilotpressure[bar]
Pilot oil cleanliness
Specialattentionmustbepaidtothepurityoftheoilfor
thepilotoilsupply;additionalpilotoilneltersmustbe
usedifnecessary.
Actuating time / dynamics
Basefrequencyinrelationtospoolstrokeapprox.14Hz
forsetpointvaluechangefrom0to100%.
Characteristic curve for step function
Viscosity[mm
2
/s]
Time[ms]
10 100 1000 10000
3
2
1
4
5 6
1000
10000
100
10
1 Actuatingtime:NeutralafterFloat
2 Actuatingtime:NeutralafterLowering
3 Actuatingtime:NeutralafterLifting
4 Delaytime:NeutralafterFloat
5 Delaytime:NeutralafterLowering
6 Delaytime:NeutralafterLifting
Thermal pressure relief valve
Optionalpressurelimitationfunctionintegrated
inthecheckvalve,whichpreventsanimpermissible
highpressurebuildingupbetweenthevalveand
thequickcouplersinstalled.
Suchpressurepeakscanoccurwhentheoilvolume
enclosedheatsup,forexample.Thepressureisrelieved
internallyinthevalve.
Symbol T-PRV
2.F
ConsumerportB
RE66176/2023-05-22,BoschRexrothAG
13 Directionalvalves | SB11-EHS4
Hydraulicfunctions
Internal leakage
Leakage in consumer port SB11-EHS4 with 1 check valve
B→Rinposition0: 2ml/min
A→Rinposition0: 60ml/min(standard)
A→Rinposition2:
(Check
functionIPC)
150ml/min(typ.)
300ml/min(max.)
Additionalleakagevaluesonrequest.
Highvaluescanoccurforspecicspoolversions.
Notice
Checkvalveleakagevaluesmeasuredwith
p=125bar,ν=30mm
2
/s,ϑ=50°C,t
waitingtime
=15s,
t
measuringtime
=60s.
LeakageP→Rmeasuredwithp=200bar.
Typical development of leakage, chronological sequence
of leak at check valve
p [bar]
V [ml]
θ [°C]
q [ml/min]
1
0
0.5
1.5
2
2.5
3.5
3
40
0
20
60
80
100
140
120
0 1 2 3 4 5 6 7 8 9 10
Time[min]
Measuring
time
Leakage[ml/min]
Pressure[bar],temperature[°C]
Pilot oil supply
Thepilotoilsupplyisnotpartofthedirectionalvalvebut
partoftheblockorsystem.
RequiredcontrolowperEHSdirectionalvalve
(applicabletoSB-EHSandEHR-EHS)
Values for aviscosity of 30 mm
2
/sec:
Typical Maximum
InNeutralposition 250ml/min 460ml/min
InLiftingorLoweringmode
600ml/min 600ml/min
InFloatmode 250ml/min 460ml/min
Duringstepfunction
(LiftingorLoweringmode)
3.5l/min
(Actuatingtimeapprox.
40ms,noramp)
Duringstepfunction
(Floatmode)
4.4l/min
(Actuatingtime
approx.75ms)
Demandpeaksinthepilotoillimitedby
Avoidingsimultaneousconnectionofseveralconsumers
(delaybyactuatingtime+safetydistance)
Programmingintimeramps
Control pressure referencing
Thepilotoilpressurep
x
mustbereferencedto
thehighestreturnowpressureofallEHSvalves.
(p
xabs.
= p
x
+p
Rmax
)
BoschRexrothAG,RE66176/2023-05-22
14
SB11-EHS4 |Directionalvalves
Electronicfunctions
Electronic functions
Notice
Safety-relevantprojectplanninginstructionscanbe
foundinthemanual66157-01-B.
Foranoverviewaswellasadetaileddescriptionof
theerrorcodes,pleaserefertomanual66157-02-B.
General information about CAN control
TheEHSvalvecanbeeasilyactuatedviatheserialCAN
interface.Inthisway,amessagecanbeusedtospecify
theoperatingmodes"Neutral","Lifting","Lowering",
"Float"aswellastheowsetpointvalue.Asecond
messagecanbeusedtosetthecharacteristiccurveform,
thecharacteristiccurveriseandtheramptimesseparately
for"Lifting"and"Lowering".Conversely,thevalvecanuse
theerrorcodetoreportthedetailsofanyfaultsthatoccur
tothesuperordinatecontrolpanel.
Thevalvecanbepermanentlyreprogrammedviathe
diagnosisinterface(CANbaudrateandidentier,
batteryvoltagelimits,valvenumber,etc.).
Characteristic curves for setpoint value generation and
time ramps
Characteristic curve rise
Thecharacteristiccurveriseisusedtoreduce
themodulationofthevalve(LiftingandLowering)
linearlyfrom100%to0%.
Thecharacteristiccurverisecanbeprogrammedinthe
rangefrom1…1000(0.1%…100%):
0x0000=0.0%ofmax.ow
0x0001=0.1%ofmax.ow
0x0002=0.2%ofmax.ow
0x03E8=100.00%ofmax.ow
Thevaluesforthecharacteristiccurveriseare
transmittedinthe"Processdatamessage".
Characteristic curve rise
0
10
20
30
40
50
60
70
80
90
100
0 10 20 30 40 50 60 70 80 90 100
0x03E8
0x0384
0x0320
0x02BC
0x0258
0x01F4
0x0190
0x012C
0x00C8
0x0096
0x0064
0x0050
0x0032
0x0014
0x0001
Input[%]
Output[%]
Input signal [%]:
Correspondstotheowsetpointvalue
Output signal [%]:
Correspondstotheowatthedirectionalvalve.
Theinputcorrespondstotheowsetpointvalueof
theswitchorjoystick.Theoutputcorrespondstothe
percentageofthemaximumow.Reducingthegradient
reducestheoutputowavailablewiththeswitchor
joystick.Italsoimprovestheowresolutionifhigher
accuracyisrequired.
RE66176/2023-05-22,BoschRexrothAG
15 Directionalvalves | SB11-EHS4
Electronicfunctions
Characteristic curve form
Thecharacteristiccurveformcanbeusedtochange
thevalvebehaviorfromlineartohighlyprogressive.
Inthisway,thenecontrolbehaviorofthevalvecanbe
changedwithonesingleoperatingelement(e.g.joystick),
ifrequired.
ForLiftingandLowering,16separatestepscanbe
programmed:
0hex(linear)toFhex(progressive).
Thevaluesforthecharacteristiccurveformare
transmittedinthe"Processdatamessage".
Characteristic curve form
10
20
30
40
50
60
70
80
90
100
10 20 30 40 50 60 70 80 90 1000
0
0x0
0xA
0xB
0xC
0xD
0xE
0xF
0x1
0x2
0x3
0x4
0x5
0x6
0x7
0x8
0x9
Input[%]
Output[%]
Input signal [%]:
Correspondstotheowsetpointvalue
Output signal [%]:
Correspondstotheowatthedirectionalvalve.
Theinputcorrespondstotheowsetpointvalue
oftheswitchorjoystick.Theoutputcorresponds
tothepercentageofthemaximumow.
Time ramps
Timerampscanbeusedselectivelytoreducethevalve
dynamics.Theramptimeisthetimerequiredtocomplete
theentirestroke(from0%to100%orfrom100%to0%
LiftingorLowering).
ForLiftingandLowering,4000separatestepscanbe
programmed,eachforincreasinganddecreasingow
setpointvalues:
0x00=0ms
0x01=1ms
0x02=2ms
...
0xFA0=4000ms
Thevaluesforthetimerampsaretransmittedinthe
"Processdatamessage".
Time ramps
0
10
20
30
40
50
60
70
80
90
100
200
400
600
800
1000
1200
1400
1600
1800
2000
2200
2400
2600
2800
3000
3200
3400
3600
3800
4000
0
0x0001
0x0032
0x0064
0x00C8
0x012C
0x0190
0x01F4
0x0258
0x02BC
0x0320
0x0384
0x03E8
0x04B0
0x05DC
0x07D0
0x0960
0x0AF0
0x0C80
0x0E10
0x0FA0
Time[ms]
Output[%]
BoschRexrothAG,RE66176/2023-05-22
16
SB11-EHS4 |Directionalvalves
Dimensions
Dimensions [mm]
Dimensions
Standard valve SB11-EHS4
130.4
222.25
206.5±1.5
61.3±1.5
31.4±0.4
92.4±0.4
20±0.4
40±0.3
8±1.5
87.4±0.643±1.5
214.25±1
21
3
4
R
P
Rx
X
LS
A B
1 Electro-hydraulicactuation(actuatingunitEHS4,seepage17)
2 Threeholesdrilledthroughformounting
3 ConsumerportsA,BinthreaddesignM18×1.5
4 Nameplate
RE66176/2023-05-22,BoschRexrothAG
17 Directionalvalves | SB11-EHS4
Dimensions
Actuating unit EHS4
47
1)
50
65
1)
102.3±1
125
93.7±1.5
-0.20
39.4
+0.15
PIN 4 = U
Bat
PIN 3 = CAN-low
PIN 2 = CAN-high
PIN 1 = Ground
Pinassignment:
AMPSuperseal,4-pin
Thread design of consumer ports Aand B
Version I
DIN3852-1(metricthread)
Forsealringsealing
Version II (preferred version)
ENISO6149-1(metricthread)
Nofemalethreadcharacterization
ForO-ringsealing
Version I Version II
1) Connectorremovaldimension
BoschRexrothAG,RE66176/2023-05-22
18
SB11-EHS4 |Directionalvalves
Installationposition
Product identication
Thevalvesectionsareidentiedbya26×15mm
adhesivelabelcontainingadatamatrixcode(6×6mm)
whichincludesanencodeduniqueserialnumber.
Forunpaintedproducts,theadhesivelabelsare
protectedbyanadditionalprotectivelm.
FD: XXXXX
XXXXX
MNR: XXXXXXXXXXXX
SN: XXXXXXXXXXXX
CNR: XXXXXXXXXXXX
Made in XXXXXXX
Installation position
SB11-EHS4
1
1)
−45°
+45°
−45°
+10°
2
+10°
−45°
+45°
−45°
3
+10°
−45°
+45°
−45°
4
1)
−45°
+45°
−45°
+45°
5
−45°
+45°
−45°
+45°
6
−45°
+45°
−45°
+45°
1) Permissiblewithrestrictions.Increasedairbleedingrequiredto
ensurefunctionandactuatingtimes.Seeinstructionmanual
66177-B.Pleasecontactus.
RE66176/2023-05-22,BoschRexrothAG
19 Directionalvalves | SB11-EHS4
Relateddocumentation
Related documentation
Document type Title Document number
Instructionmanual Load-sensingcontrolblockSB11-EHS4 66177-B
1)
Datasheet Load-sensingcontrolblockSB11-EHS4 66177
Platesforload-sensingcontrolblockSB11-EHS4 66181
HitchcontrolvalvesEHR11-EHS4 66126
Mineraloil-basedhydraulicuids 90220
Repairmanual ControlblockassemblySB11-EHS4 66177-10-R
RepairingthedirectionalvalvesSB11-EHS4 66177-20-R
RepairofplatesSB11 66177-50-R
1)
Technicalinformation Interfacedescription,hydraulics Z206803930
PilotmoduleEHS4–safety-relevantprojectplanninginstructions 66157-01-B
PilotmoduleEHS4–TechnicalCustomerDocumentation(TKU) 66157-02-B
1) Inpreparation
Abbreviations
Thisdocumentationusesthefollowingabbreviations:
Abbreviation Meaning
AP Connectingplate
CAN ControllerAreaNetwork
CANFD CANexibledatarate
EHR Electrohydraulichitchcontrol
EHS Pilotoperatedelectro-hydraulicactuatingunit
EMC Electromagneticcompatibility
EP Endplate
ESD Electrostaticdischarge
EVR Endvalve,LSdirectionright
IPC Individualpressurecompensator
LS Load-sensing
OBE On-boardelectronics
SVR Standardvalve,LSdirectionright
T-PRV Thermalpressurereliefvalve
Spare parts
Forspareparts,visit
www.boschrexroth.com/spc
Contact partners for accessories and spare parts
Accessoriesandsparepartsareavailable:
Fromthevehiclemanufacturer(specialistdealer).
Fromthesystemmanufacturer.
FromyourBoschRexrothspecialistdealer.
RexrothsalespartnerscanbefoundontheInternetat
www.boschrexroth.com/addresses
Ifyouhavequestionsregardingspareparts,pleasecontact
yourlocalRexrothserviceortheservicedepartmentofthe
controlblockmanufacturer.
BoschRexrothAG
Robert-Bosch-Straße2
71701Schwieberdingen
Germany
Tel.:+49(0)711-811-8481
Service.ma.schwieberdingen@boschrexroth.de
BoschRexrothAG,RE66176/2023-05-22
BoschRexrothAG
Robert-Bosch-Straße 2
71701 Schwieberdingen
Germany
Phone: +49 711 811-8481
info.ma@boschrexroth.de
www.boschrexroth.com
©BoschRexrothAG2021. All rights reserved, also regarding any disposal,
exploitation, reproduction, editing, distribution, as well as in the event of
applications for industrial property rights. The data specied within only
serves todescribe the product. No statements concerning acertain condition
or suitability for acertain application can be derived from our information.
The information given does not release the user from the obligation of own
judgment and verication. It must be remembered that our products are
subject to anatural process of wear and aging.
20 SB11-EHS4 |Directionalvalves
Relateddocumentation